Enecsys Single Repeater Technické informace

Procházejte online nebo si stáhněte Technické informace pro Bridge a opakovače Enecsys Single Repeater. Enecsys Single Repeater System information Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 50
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
O P T I M A L
S OLA R
S O L UTION S
E nec sys E n a b les
Enecsys Micr o inv e rte r s
Enecsys Ga t e w a y
Enecsys Repeater
Enecsys Doub le Rep e a t e r
www.enecsys.com
Document Number: IOG010212
Version: 1.6
June 6, 2012
Enecsys Installation and Operation Guide
intelligent reliable power
Zobrazit stránku 0
1 2 3 4 5 6 ... 49 50

Shrnutí obsahu

Strany 1 - S O L UTION S

O P T I M A L S OLA R S O L UTION SE nec sys E n a b lesEnecsys Micr o inv e rte r sEnecsys Ga t e w a yEnecsys RepeaterEnecsys Doub le Rep e a t e

Strany 2 - Table of Contents

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 10 2 Installation Sequence 2.1 Customer site inspection CAUTION: All work

Strany 3 - 3

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 11 Q:#Why#is#it#recommended#to#set#up#the#gateway#as#early#as#possible#duri

Strany 4 - 1.1 Audience

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 12 2.9 Set up the new installation on the Enecsys monitoring website WARNING

Strany 5 - 1.4 Safety

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 13 3 Installing the Gateway • The gateway is connected to the Inter

Strany 6

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 14 CAUTION: the gateway must only be used with the antenna that is already fi

Strany 7

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 15 3.2 Connecting the gateway • The Enecsys gateway requires the following

Strany 8

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 16 4 Using the Enecsys Gateway The gateway should already be installed: see S

Strany 9

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 17 • To select Installer Mode, press the Installer Mode switch with the s

Strany 10 - 2 Installation Sequence

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 18 4.1.5 Installer Mode screen symbols Screen Symbol Description “ENECSYS” i

Strany 11 - 11

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 19 5 Using Enecsys Repeaters The Enecsys gateway receives signals from

Strany 12

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 2 Table of Contents 1 Important Safety Instructions 4!1.1 Audience 4!1.2 Pr

Strany 13 - 3 Installing the Gateway

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 20 5.3 Using the double repeater with external antenna Even with a single rep

Strany 14 - 3.1 Mounting the gateway

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 21 5.4 Installing one or more single repeaters The single repeater shoul

Strany 15 - 3.2 Connecting the gateway

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 22 5.4.1 Mounting the single repeater • The single repeater must be installe

Strany 16 - 4 Using the Enecsys Gateway

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 23 5.5 Installing a double repeater The double repeater can be installed an

Strany 17 - 17

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 24 5.5.2 Mounting the external antenna • The external antenna must be

Strany 18 - Description

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 25 Connections for the double repeater: o 5V DC power input from the plug

Strany 19 - 5 Using Enecsys Repeaters

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 26 6 Installing the micro inverters • Note that a Torx t20 driver is require

Strany 20

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 27 Single micro inverters are available in the following models with variou

Strany 21 -

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 28 6.2 Mounting the single micro inverter The single micro inverter has seve

Strany 22

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 29 6.3 Duo micro inverter A Enecsys duo micro inverter B Distribution un

Strany 23 - 23

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 3 5.5 Installing a double repeater 23!5.5.1 Mounting the double repeater

Strany 24

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 30 Duo micro inverters are available in the following models with two differe

Strany 25 - 25

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 31 Duo micro inverter scope of delivery: • 1 Enecsys duo micro inverter u

Strany 26 - 6.1 Single micro inverter

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 32 6.4 Mounting the duo micro inverter The duo micro inverter has several mo

Strany 27

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 33 Secure the inverter to the mounting structure. Mounting methods may va

Strany 28

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 34 • An AC bus extension cable can connect one distribution unit to another.

Strany 29 - 6.3 Duo micro inverter

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 35 ATTENTION: Do not allow the cable to lie in contact with the roof surf

Strany 30

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 36 ❸Connect the AC bus extension cable to the distribution unit.#Repeat step

Strany 31 - 31

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 37 ❺b#Duo micro inverter:#Connect both Y connectors to the appropriate mic

Strany 32

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 38 6.6.2 Disconnecting a micro inverter CAUTION: micro inverters must be d

Strany 33 - 33

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 39 7 Monitoring Setup and Installation Launch 7.0 Installer login • Instal

Strany 34 - AC BRANCH CABLE

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 4 1 Important Safety Instructions SAVE THESE INSTRUCTIONS – This manual co

Strany 35

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 40 Step 3: Input the system information. • System information describes the

Strany 36 - ❺a Single Micro inverter:

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 41 Step 5: Begin layout by adding a section. • Before any sections are cre

Strany 37 - 37

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 42 Step 7: Adjust section layout. • Double-clicking on the section will all

Strany 38

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 43 Installation#Layout#Tools#Key# Select All Align Vertically, Left or Ri

Strany 39 - 7.0 Installer login

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 44 • The SERIALS tab allows the user to manually load the inverter serial nu

Strany 40

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 45 numbers will automatically be reporting on the list of available serial

Strany 41 - Section#Details#

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 46 Step 4: Inform the customer • Click the NEW USER button for the

Strany 42

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 47 8 Troubleshooting Contact Enecsys support or the system installer for as

Strany 43

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 48 9 Product return process If an Enecsys micro inverter is experiencing a pr

Strany 44

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 49 10 PV module / micro inverter serial number form Print out this form: ma

Strany 45 - 45

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 5 1.3 Conventions used in this manual The following conventions are use

Strany 46 - Step 4: Inform the customer

Enecsys Limited was founded in 2003 and develops, manufactures and markets innovative grid-connected micro inverters for solar photovoltaic systems in

Strany 47 - 8 Troubleshooting

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 6 WARNING Isolation of the AC cabling The AC wiring from the inverters

Strany 48 - 9 Product return process

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 7 1.5 Installation compliance requirements • The Installation must be

Strany 49 - 49

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 8 For the USA: National Electrical Code, ANSI NFPA 70 For Canada: Canadian El

Strany 50

Enecsys Installation and Operation Manual – Version 1.6 –June 6 2012 9 WARNING: Do not connect this or any other Enecsys micro inverter to an e

Komentáře k této Příručce